Tomzn Tovpd1-60-ec Manual Jun 2026
Ensure that the load is turned on. If the load exceeds the limit set in P5 , the device will trip. Increase the P5 value if your household consumption safely permits it.
To adjust the over/under voltage trip points without the app, follow this manual procedure:
Check the input connections ( IN terminals) with a multimeter to verify that 230V AC power is actively reaching the device.
| Problem | Possible cause | Solution | |---------|----------------|----------| | Load always off, red LED solid | Voltage out of range (check with meter) | Wait for grid recovery or adjust setpoints | | Green LED off, no output | No input power / internal fuse blown | Check upstream breaker, replace device if dead | | Rapid on/off cycling | Loose neutral connection | Tighten N terminals at unit and mains | | Auto-reset never happens | Unit in permanent fault mode | Cycle mains power; if persists, replace unit | | Unit hot (>50°C) | Overload >60A or poor ventilation | Reduce load, increase air gap around DIN rail | tomzn tovpd1-60-ec manual
: Limits current to prevent circuit damage (adjustable up to 63A). Automatic Recovery
Mains IN TOVPD1-60-EC Load OUT L (brown) ---------> [L IN] [L OUT] --------> L to load N (blue) ---------> [N IN] [N OUT] --------> N to load | | (internal path - verify continuity)
Check if the "A6" delay timer is still counting down. A small light or flashing digit usually indicates the recovery delay is active. Ensure that the load is turned on
Once the utility grid stabilizes within the recovery limits ( P2 and P4 ), the recovery timer ( P6 ) triggers. After the countdown completes, the device automatically reconnects power to your appliances. 6. Troubleshooting Common Issues
: Always connect Line (Phase) to the L terminals and Neutral to the N terminals. Step-by-Step Installation
:
The TOMZN TOVPD1-60-EC is an adjustable, DIN-rail mounted protection device that integrates over-voltage, under-voltage, and over-current protection with real-time digital monitoring . It is designed for single-phase systems and can instantly disconnect the power supply to prevent equipment damage during electrical faults. Parameter Specification Model TOVPD1-60-EC Power Supply 230V AC, 50/60Hz Max Loading Power
140V–210V (Default: 170V)
The of your main supply circuit breaker Any specific error codes showing on the LED display To adjust the over/under voltage trip points without
The bottom screen will display the exact value that caused the trip. 3.5. Restoring Factory Settings Long-press the button for 12 seconds. 4. Key Considerations & Troubleshooting
: When illuminated, the digital screen is displaying the active grid voltage.